Showing 577–588 of 670 results

Schneider R9F32363, 3P, 63A, Resi9, Miniature circuit breaker (MCB), C curve, 4500A (IEC/EN 60898-1)

In stock

1,586 EGP
Brand

Schneider

part number

R9F32363

Poles description

3P

[In] rated current

63 A

Breaking capacity

4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1

Standards

EN/IEC 60898-1

[Ui] rated insulation voltage

440 V AC

[Uimp] rated impulse withstand voltage

4 kV

9 mm pitches

6

Height

81 mm

Width

54 mm

Depth

72 mm

Embedding depth

44 mm

weight

240 g

Schneider R9R51225, 2P, 25A, Resi9, Residual current circuit breaker (RCCB), AC type, 30mA

In stock

3,496 EGP
Brand

Schneider

Part Number

R9R51225

Poles description

2P

[In] rated current

25 A

Earth-leakage sensitivity

30 mA

Rated breaking and making capacity

Im 500 A conforming to EN/IEC 61008

Rated conditional short-circuit current

Inc 6 kA

[Ui] rated insulation voltage

440 V

[Uimp] rated impulse withstand voltage

4 kV

Surge current

250 A

9 mm pitches

4

Height

81 mm

Width

36 mm

Depth

73 mm

weight

180 g

Embedding depth

44 mm

Colour

White

Schneider R9R51240, 2P, 40A, Resi9, Residual current circuit breaker (RCCB), 30mA, AC type

In stock

2,419 EGP
Brand

Schneider

part number

R9R51240

Poles description

2P

[In] rated current

40 A

Earth-leakage sensitivity

30 mA

Rated breaking and making capacity

Im 500 A conforming to EN/IEC 61008

Rated conditional short-circuit current

Inc 6 kA

[Ui] rated insulation voltage

440 V

[Uimp] rated impulse withstand voltage

4 kV

Surge current

250 A

9 mm pitches

4

Height

81 mm

Width

36 mm

Depth

73 mm

weight

180 g

Embedding depth

44 mm

Schneider R9R51425, 4P, 25A, Resi9, Residual current circuit breaker (RCCB), AC type, 30mA

In stock

2,948 EGP
Brand

Schneider

Part Number

R9R51425

Poles description

4P

[In] rated current

25 A

Earth-leakage sensitivity

30 mA

Earth-leakage protection time delay

Instantaneous

Rated breaking and making capacity

Im 500 A conforming to EN/IEC 61008

Rated conditional short-circuit current

Inc 6 kA

Network frequency

50/60 Hz

[Ue] rated operational voltage

400 V AC 50/60 Hz

Residual current tripping technology

Voltage independent

[Ui] rated insulation voltage

440 V

[Uimp] rated impulse withstand voltage

4 kV

Surge current

250 A

9 mm pitches

8

Height

81 mm

Width

72 mm

weight

370 g

depth

44 mm

Schneider R9R51440, 4P, 40A, Resi9, Residual current circuit breaker (RCCB), AC type, 30mA

In stock

5,106 EGP
Brand

Schneider

part number

R9R51440

Poles description

4P

[In] rated current

40 A

Earth-leakage sensitivity

30 mA

Rated breaking and making capacity

Im 500 A conforming to EN/IEC 61008

Rated conditional short-circuit current

Inc 6 kA

[Ue] rated operational voltage

400 V AC 50/60 Hz

[Ui] rated insulation voltage

440 V

[Uimp] rated impulse withstand voltage

4 kV

Surge current

250 A

9 mm pitches

8

Height

81 mm

Width

72 mm

Depth

73 mm

weight

370 g

Embedding depth

44 mm

Schneider R9R51463, 4P, 63A, Resi9, Residual current circuit breaker (RCCB), 30mA, AC type

In stock

5,273 EGP
Brand

Schneider

Part Number

R9R51463

Poles description

4P

[In] rated current

63 A

Earth-leakage sensitivity

30 mA

Rated breaking and making capacity

Im 630 A conforming to EN/IEC 61008

Rated conditional short-circuit current

Inc 6 kA

[Ui] rated insulation voltage

440 V

[Uimp] rated impulse withstand voltage

4 kV

Surge current

250 A

9 mm pitches

8

Height

81 mm

Width

72 mm

Depth

73 mm

weight

370 g

Embedding depth

44 mm