Schneider A9F77332, 3P, 32A, Acti9 iC60N, Miniature circuit breaker (MCB), C curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)
In stock
1,526 EGP
Order Via Whatsapp Brand |
Schneider |
---|---|
Part Number |
A9F77332 |
Poles description |
3P |
[In] rated current |
32 A |
Network type |
AC |
Utilisation category |
Category A conforming to EN 60947-2 |
Standards |
IEC 60898-1 |
Quality labels |
NF |
[Ui] rated insulation voltage |
500 V AC 50/60 Hz conforming to EN 60947-2 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to EN 60947-2 |
9 mm pitches |
6 |
Height |
85 mm |
Width |
54 mm |
Depth |
78.5 mm |
weight |
0.375 kg |
Warranty |
18 months |
Schneider A9F77163, 1P, 63A, Acti9 iC60N, Miniature circuit breaker (MCB), C curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)
In stock
440 EGP
Order Via Whatsapp Brand |
Schneider |
---|---|
Part Number |
A9F77163 |
Poles description |
1P |
[In] rated current |
63 A |
Breaking capacity |
6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
Utilisation category |
Category A conforming to EN 60947-2 |
[Ui] rated insulation voltage |
500 V AC 50/60 Hz conforming to EN 60947-2 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to EN 60947-2 |
9 mm pitches |
2 |
Height |
85 mm |
Width |
18 mm |
Depth |
78.5 mm |
weight |
0.215 kg |
Warranty |
18 months |
Schneider R9R51425, 4P, 25A, Resi9, Residual current circuit breaker (RCCB), AC type, 30mA
In stock
2,948 EGP
Order Via Whatsapp Brand |
Schneider |
---|---|
Part Number |
R9R51425 |
Poles description |
4P |
[In] rated current |
25 A |
Earth-leakage sensitivity |
30 mA |
Earth-leakage protection time delay |
Instantaneous |
Rated breaking and making capacity |
Im 500 A conforming to EN/IEC 61008 |
Rated conditional short-circuit current |
Inc 6 kA |
Network frequency |
50/60 Hz |
[Ue] rated operational voltage |
400 V AC 50/60 Hz |
Residual current tripping technology |
Voltage independent |
[Ui] rated insulation voltage |
440 V |
[Uimp] rated impulse withstand voltage |
4 kV |
Surge current |
250 A |
9 mm pitches |
8 |
Height |
81 mm |
Width |
72 mm |
weight |
370 g |
depth |
44 mm |
Schneider A9F77132, 1P, 32A, Acti9 iC60N, Miniature circuit breaker (MCB), C curve
In stock
317 EGP
Order Via Whatsapp Brand |
Schneider |
---|---|
Part Number |
A9F77132 |
Poles description |
1P |
[In] rated current |
32 A |
Standards |
IEC 60898-1 |
[Ui] rated insulation voltage |
500 V AC 50/60 Hz conforming to EN 60947-2 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to EN 60947-2 |
9 mm pitches |
2 |
Height |
85 mm |
Width |
18 mm |
Depth |
78.5 mm |
weight |
0.215 kg |
Warranty |
18 months |
Schneider R9R51225, 2P, 25A, Resi9, Residual current circuit breaker (RCCB), AC type, 30mA
In stock
3,496 EGP
Order Via Whatsapp Brand |
Schneider |
---|---|
Part Number |
R9R51225 |
Poles description |
2P |
[In] rated current |
25 A |
Earth-leakage sensitivity |
30 mA |
Rated breaking and making capacity |
Im 500 A conforming to EN/IEC 61008 |
Rated conditional short-circuit current |
Inc 6 kA |
[Ui] rated insulation voltage |
440 V |
[Uimp] rated impulse withstand voltage |
4 kV |
Surge current |
250 A |
9 mm pitches |
4 |
Height |
81 mm |
Width |
36 mm |
Depth |
73 mm |
weight |
180 g |
Embedding depth |
44 mm |
Colour |
White |
Schneider R9F32110, 1P, 10A, Resi9, Miniature circuit breaker (MCB), C curve, 4500A (IEC/EN 60898-1)
In stock
264 EGP
Order Via Whatsapp Brand |
Schneider |
---|---|
Part Number |
R9F32110 |
Poles description |
1P |
[In] rated current |
10 A |
Breaking capacity |
4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
Standards |
EN/IEC 60898-1 |
[Ui] rated insulation voltage |
440 V AC |
[Uimp] rated impulse withstand voltage |
4 kV |
9 mm pitches |
2 |
Height |
81 mm |
Width |
18 mm |
Depth |
72 mm |
Embedding depth |
44 mm |
weight |
240 g |
Schneider R9F32116, 1P, 16A, Resi9, Miniature circuit breaker (MCB), C curve, 4500A (IEC/EN 60898-1)
In stock
264 EGP
Order Via Whatsapp Brand |
Schneider |
---|---|
Part Number |
R9F32116 |
Poles description |
1P |
[In] rated current |
16 A |
Breaking capacity |
4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
Standards |
EN/IEC 60898-1 |
[Ui] rated insulation voltage |
440 V AC |
[Uimp] rated impulse withstand voltage |
4 kV |
9 mm pitches |
2 |
Height |
81 mm |
Width |
18 mm |
Depth |
72 mm |
Embedding depth |
44 mm |
weight |
240 g |