Schneider R9F32240, 2P, 40A, Resi9, Miniature circuit breaker (MCB), C curve,  4500A (IEC/EN 60898-1)

In stock

693 EGP
Brand

Schneider

Part Number

R9F32240

Poles description

2P

[In] rated current

40 A

Breaking capacity

4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1

Standards

EN/IEC 60898-1

[Ue] rated operational voltage

400 V AC 50/60 Hz

[Ui] rated insulation voltage

440 V AC

[Uimp] rated impulse withstand voltage

4 kV

9 mm pitches

4

Height

81 mm

Width

36 mm

Depth

72 mm

Embedding depth

44 mm

weight

240 g

Schneider A9F77120, 1P, 20A, Acti9 iC60N, Miniature circuit breaker (MCB), C curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)

In stock

317 EGP
Brand

Schneider

Part Number

A9F77120

Poles description

1P

[In] rated current

20 A

Breaking capacity

6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
10 kA Icu at <= 72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2
10 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2

Utilisation category

Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2

Standards

EN 60898-1
IEC 60898-1
EN 60947-2
IEC 60947-2

Quality labels

NF

[Ui] rated insulation voltage

500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2

[Uimp] rated impulse withstand voltage

6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2

9 mm pitches

2

Height

85 mm

Width

18 mm

Depth

78.5 mm

weight

0.215 kg

Warranty

18 months

Schneider A9F77163, 1P, 63A, Acti9 iC60N, Miniature circuit breaker (MCB), C curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)

In stock

440 EGP
Brand

Schneider

Part Number

A9F77163

Poles description

1P

[In] rated current

63 A

Breaking capacity

6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
10 kA Icu at <= 72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2
10 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2

Utilisation category

Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2

[Ui] rated insulation voltage

500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2

[Uimp] rated impulse withstand voltage

6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2

9 mm pitches

2

Height

85 mm

Width

18 mm

Depth

78.5 mm

weight

0.215 kg

Warranty

18 months

Schneider R9R51425, 4P, 25A, Resi9, Residual current circuit breaker (RCCB), AC type, 30mA

In stock

2,948 EGP
Brand

Schneider

Part Number

R9R51425

Poles description

4P

[In] rated current

25 A

Earth-leakage sensitivity

30 mA

Earth-leakage protection time delay

Instantaneous

Rated breaking and making capacity

Im 500 A conforming to EN/IEC 61008

Rated conditional short-circuit current

Inc 6 kA

Network frequency

50/60 Hz

[Ue] rated operational voltage

400 V AC 50/60 Hz

Residual current tripping technology

Voltage independent

[Ui] rated insulation voltage

440 V

[Uimp] rated impulse withstand voltage

4 kV

Surge current

250 A

9 mm pitches

8

Height

81 mm

Width

72 mm

weight

370 g